YOCTO NET D6 WEB 85÷265V WEB DATA MANAGER Network bridge between the Ethernet network (Modbus TCP/IP protocol) and the RS485 line (Modbus RTU protocol) for communication and data collection of Electrex devices. FSTN graphic display. Modbus-TCP Server (max. 4 simultaneous connections). Astronomical and perpetual clock/calendar, battery powered and non-volatile, industrial type memory. Remote firmware update. Built-in WEB Server including Upgrade Web option: standard web pages for real-time measures displaying. Other functions can be activated via firmware upgrade (PUK entry). FTP Server. ExpBus, high speed communication, port for external devices (inputs and outputs modules, and environmental sensors). Equipped with NFC technology. DIN rail mount 6 modules. Wide range power supply 85÷265V/100÷374VDC. |
|||
|
|
YOCTO NET D6 WEB LOG 8 85÷265V 2DI 2DO WEB DATA MANAGER Network bridge between the Ethernet network (Modbus TCP/IP protocol) and the RS485 line (Modbus RTU protocol) for communication and data-logging of Electrex devices. FSTN graphic display. Modbus-TCP Server (max. 4 simultaneous connections). Astronomical and perpetual clock/calendar, battery powered and non-volatile, industrial type memory. Remote firmware update. Built-in WEB Server including Upgrade Web option: standard web pages for real-time measures displaying. Already activated one Log 8 logging service (log of 8 Electrex instruments/Modbus registers, power / energy and digital inputs). Other functions can be activated via firmware upgrade (PUK entry). FTP Server. 2 digital inputs and 2 digital outputs. ExpBus, high speed communication, port for external devices (inputs and outputs modules, and environmental sensors). Equipped with NFC technology. DIN rail mount 6 modules. Wide range power supply 85÷265V/100÷374VDC. |
|||
|
|
YOCTO NET WI-FI EDA D6 WEB LOG 8 85-265V 2DI 2DO WEB DATA MANAGER Network bridge between the Ethernet and/or Wi-Fi network (Modbus TCP/IP protocol) and the RS485 line (Modbus RTU protocol) for communication and data-logging of Electrex devices. Wi-Fi connection via external antenna cod. PFC3530 (included); compliant with IEEE 802.11b/g/n. FSTN graphic display. Modbus-TCP Server (max. 4 simultaneous connections). Astronomical and perpetual clock/calendar, battery powered and non-volatile, industrial type memory. Remote firmware update. Built-in WEB Server including Upgrade Web option: standard web pages for real-time measures displaying. Already activated one Log 8 logging service (log of 8 Electrex instruments/Modbus registers, power / energy and digital inputs). Other functions can be activated via firmware upgrade (PUK entry). FTP Server. 2 digital inputs and 2 digital outputs. ExpBus, high speed communication, port for external devices (inputs and outputs modules, and environmental sensors). Equipped with NFC technology. DIN rail mount 6 modules. Wide range power supply 85÷265V/100÷374VDC. |
|||
|
|
YOCTO NET D6 WEB LOG 8 FULL 85÷265V 2DI 2DO WEB DATA MANAGER Network bridge between the Ethernet network (Modbus TCP/IP protocol) and the RS485 line (Modbus RTU protocol) for communication and data-logging of Electrex devices. FSTN graphic display. Modbus-TCP Server (max. 4 simultaneous connections). Astronomical and perpetual clock/calendar, battery powered and non-volatile, industrial type memory. Remote firmware update. Built-in WEB Server including Upgrade Web option: standard web pages for real-time measures displaying. Already activated one Log 8 logging service (log of 8 Electrex instruments/Modbus registers, power / energy and digital inputs), Upgrade Charts for historical data displaying on graphs, Upgrade Energy Automation, E-Mail/Sms and Calendars. FTP Server. 2 digital inputs and 2 digital outputs. ExpBus, high speed communication, port for external devices (inputs and outputs modules, and environmental sensors). Equipped with NFC technology. DIN rail mount 6 modules. Wide range power supply 85÷265V/100÷374VDC. |
|||
|
|
YOCTO NET D6 WEB LOG 40 85÷265V 2DI 2DO WEB DATA MANAGER Network bridge between the Ethernet network (Modbus TCP/IP protocol) and the RS485 line (Modbus RTU protocol) for communication and data-logging of Electrex devices. FSTN graphic display. Modbus-TCP Server (max. 4 simultaneous connections). Astronomical and perpetual clock/calendar, battery powered and non-volatile, industrial type memory. Remote firmware update. Built-in WEB Server including Upgrade Web option: standard web pages for real-time measures displaying. Already activated 5 x Log 8 logging service (log of 39 Electrex instruments/Modbus registers, power / energy and digital inputs). Other functions can be activated via firmware upgrade (PUK entry). FTP Server. 2 digital inputs and 2 digital outputs. ExpBus, high speed communication, port for external devices (inputs and outputs modules, and environmental sensors). Equipped with NFC technology. DIN rail mount 6 modules. Wide range power supply 85÷265V/100÷374VDC. |
|||
![]() |
|
|||
![]() |
NET UPGRADE LOG 8 (PUK)
Software implementation through PUK code. Adds 1 storage service, Log 8, to the Kilo net, Exa net, Femto ECT net, Femto 25A D Net and Yocto net D6 product families. It is possible to manage up to a maximum of 8 storage services for each device. |
|||
![]() |
Software implementation through PUK code. Doubbles the capacity of the storage services from Log 8 to Log 16. Available for the Kilo net log and Yocto net D6 log only. |
|||
![]() |
Software implementation through PUK code. Adds to the product families Kilo net, Exa net, Femto ECT net, Femto 25A D Net and Yocto net D6 the possibility to create custom web pages. |
|||
![]() |
Software implementation through PUK code. Allows to display on a web page charts, with configurable intervals, of electricity, temperature, humidity, luminosity, etc. obtained from the files stored in the Kilo net, Exa net, Femto ECT net, Femto 25A D Net and Yocto net D6 with the possibility to export to CSV files. |
|||
![]() |
Software implementation through PUK code. Allows to modify an existing logging service Log 8 in the Kilo net log (on request for the Exa net log, Femto ECT net log, Femto 25A D net log and Yocto net D6 log). For example for running measurement campaigns and / or increase / decrease the sampling frequency and the number of days logged. |
|||
![]() |
Software implementation through PUK code entry. Adds to the product families Kilo net, Exa net, Femto ECT net, Femto 25A D net and Yocto net D6 the ability to send email notifications/alarms related to parameters measured from the device (Modbus registers or input status). In the Net version of the devices, using the upgrade Energy Automation, it is possible to extend this functionality also for parameters retrieved from devices connected in a sub network via Rs485. |
|||
![]() |
Software implementation through PUK code entry. Adds to the product families Kilo net, Exa net, Femto ECT net, Femto 25A D net and Yocto net D6 the ability to send SMS notifications/alarms related to parameters measured from the device (Modbus registers or input status). Router Wi-Fi UMTS cod. PFC3510 with data SIM needed. In the Net version of the devices, using the upgrade Energy Automation, it is possible to extend this functionality also for parameters retrieved from devices connected in a sub network via Rs485. |
|||
![]() |
NET UPGRADE ENERGY AUTOMATION (PUK) Software implementation through PUK code entry. Allows to program, via the web interface of the Kilo net (on request also for Exa net, Femto ECT net, Femto 25A D net and Yocto net D6) Energy Automation applications for simple or complex taks such as ON/OFF switching, alarms/notifications and automations conditioned from events in order to assure a higher energy efficiency of the systems. Adding the Calendars upgrade it ispossible to schedule the automation tasks using customizable calendars. While adding the email / SMS upgrade it is possible to integrate also the sending of e-mail and/or SMS. |
|||
![]() |
Software implementation through PUK code. Adds to the Kilo net, Exa net, Femto ECT net, Femto 25A D net and Yocto net D6 the ability to manage Energy Automation functions such as on / off switches, alarms / alerts and automatisms conditioned to events and / or an annual calendar configurable in minutes / hours / days / months. |
|||
![]() |
NET UPGRADE BUNDLE ENERGY AUTOMATION, CALENDARS, EMAIL (PUK) Bundle including the software implementations (PUK): cod. PFSU940-16 Net Upgrade Energy Automation, PFSU940-20 Net Upgrade Calendars and PFSU940-15 Net Upgrade email. |
|||
![]() |
NET UPGRADE BUNDLE ENERGY AUTOMATION, CALENDARS, EMAIL, SMS (PUK) Bundle including the software implementations (PUK): cod. PFSU940-16 Net Upgrade Energy Automation, PFSU940-20 Net Upgrade Calendars, PFSU940-15 Net Upgrade email and PFSU940-17 Net Upgrade SMS. |
|||
![]() |
NET UPGRADE SENDING FILES (PUK) Software implementation through PUK code entry. Adds to the product families Kilo net, Exa net, Femto ECT net, Femto 25A D net and Yocto net D6 the possibility to send / push and save into a remote FTP server an Xml standard file (customizable on request) containing data stored in the log services. Adding the PUK Energy Automation it is possible to relate the sending of the file with also complex events/scenarios. |
|||
![]() |
Upgrade to the new firmware versions of Kilo net, Exa net, Femto ECT net, Femto 25A D net and Yocto net D6 adding new features to the instruments. |