Femto 4Hall D6

DC Energy Analyzer & Data Manager with RJ45 Ethernet port. DC monitoring (4 inputs suitable for split CT  CTS DC Hall  series - not included). FSTN graphic display. Measurement of voltage, current, power, energy, MIN-MAX voltage, MAX current. reading of the internal registers via Rj45 port  using Modbus/TCP protocol. Perennial, battery powered, astronomical clock / calendar and non volatile, industrial  memory for the logging of the load profile and energy consumed/produced. WEB and FTP server. Additional functions  enabled via PUK code entry. Firmware update remotely.



Femto 4Hall D6

DC Energy Analyzer & Web Data Manager with RJ45 Ethernet port. DC monitoring (4 inputs suitable for split CT  CTS DC Hall  series - not included). FSTN graphic display. Measurement of voltage, current, power, energy, MIN-MAX voltage, MAX current. reading of the internal registers via Rj45 port  using Modbus/TCP protocol. Network bridge between the RJ45 port and RS485 port for Modbus communication with other Electrex devices in the subnetwork. Perennial, battery powered, astronomical clock / calendar and non volatile, industrial  memory. Includes Upgrade Log 8 for the logging of the load profile and energy consumed/produced, Upgrade WEB for  displaying live measurements on the web interface. Web and FTP server. Firmware update remotely.



Femto 4Hall D6

DC Energy Analyzer & Web Data Manager with RJ45 Ethernet port. DC monitoring (4 inputs suitable for split CT  CTS DC Hall  series - not included). FSTN graphic display. Measurement of voltage, current, power, energy, MIN-MAX voltage, MAX current. reading of the internal registers via Rj45 port  using Modbus/TCP protocol. Network bridge between the RJ45 port and RS485 port for Modbus communication with other Electrex devices in the subnetwork. Perennial, battery powered, astronomical clock / calendar and non volatile, industrial  memory. Includes Upgrade Log 8 for the logging of the load profile and energy consumed/produced, Upgrade Web and Charts for  displaying live measurements and historical data (graphs) on the web interface. Web and FTP server. Firmware update remotely.



Femto 4Hall D6

DC Energy Analyzer & Wi-Fi Web Data Manager  Wi-Fi communication via external antenna  cod. PFC3530 (included). DC monitoring (4 inputs suitable for split CT  CTS DC Hall  series - not included). FSTN graphic display. Measurement of voltage, current, power, energy, MIN-MAX voltage, MAX current. reading of the internal registers via Rj45 and / or Wi-Fi port  using Modbus/TCP protocol. Network bridge between the RJ45 port and RS485 port for Modbus communication with other Electrex devices in the subnetwork. Perennial, battery powered, astronomical clock / calendar and non volatile, industrial  memory. Includes Upgrade Log 8 for the logging of the load profile and energy consumed/produced, Upgrade WEB for  displaying live measurements on the web interface. Web and FTP server. Firmware update remotely.



PFA6471-02  FEMTO D4 DC RS485 230-240V ENERGY ANALYZER



DC energy counter/analyzer with a LCD backlit display. Suitable for photovoltaic or battery systems. Measures voltage (max and min), current (max and min), power and energy. 60mV or 100mV current input for the shunts (not included - see Shunt section). Built in RS485 port. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply.



PFA6471-12  FEMTO D4 DC RS485 230-240V 1DI 2DO ENERGY ANALYZER



LCD display. DIN rail mount 4 modules. RS485 port, 1 Digital Input, 2 Digital Outputs. 230-240 V Power supply.



PFA6471-18  FEMTO D4 DC RS485 18÷60VDC 1DI 2DO ENERGY ANALYZER



LCD display. DIN rail mount 4 modules. RS485 port, 1 Digital Input and 2 Digital Outputs self powered. 18÷60Vdc Power supply.



PFA6481-02  FEMTO D4 DC 3I RS485 230-240V TRANSDUCER / ANALYZER



DC energy counter/analyzer with a LCD backlit display. Suitable for photovoltaic or battery systems. Measures voltage (max and min), current (max and min), power and energy. Three 60mV or 100mV current inputs for the shunts (not included - see Shunt section). Built in RS485 port. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply.



PFA6481-12  FEMTO D4 DC 3I RS485 230-240V 1DI 2DO TRANSDUCER / ANALYZER



DC energy counter/analyzer with a LCD backlit display. Suitable for photovoltaic or battery systems. Measures voltage (max and min), current (max and min), power and energy. Three 60mV or 100mV current inputs for the shunts (not included - see Shunt section). Built in RS485 port. 1 digital input and 2 digital outputs. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply.



PFA64B1-02  FEMTO D4 DC HALL RS485 230-240V



DC energy counter/analyzer with a LCD backlit display. Suitable for photovoltaic or battery systems. Measures voltage (max and min), current (max and min), power and energy. 4V input for a split current transformer of the Split CTS DC Mini Series DC (see Split CT Mini Series section). Built in RS485 port. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply.



PFA647H-02  FEMTO D4 DC E-WI HI 230-240V ENERGY ANALYZER



DC energy transducer / analyzer suitable for photovoltaic or battery systems with backlighted LCD graphic display. Built in RS485 port. Transceives the data via radio waves (wireless) using the E-Wi protocol. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply.



PFA7471-02  ATTO D4 DC RS485 230-240V ENERGY ANALYZER

ATTO D4 DC RS485 230-240V TRANSDUCER / ENERGY ANALYZER

Cod. PFA7471-02

DC energy transducer / analyzer suitable for photovoltaic or battery systems. 60mV or 100mV current input for the shunts (not included - see Shunt section). Built in RS485 port. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply.



ATTO D4 DC RS485 230-240V 1DI 2DO TRANSDUCER / ENERGY ANALYZER

Cod. PFA7471-12

DC energy transducer / analyzer suitable for photovoltaic or battery systems. 60mV or 100mV current input for the shunts (not included - see Shunt section). Built in RS485 port, 1 digital input and 2 digital outputs. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply.



PFA7481-02  ATTO D4 DC 3I RS485 230-240V ENERGY ANALYZER

ATTO D4 DC 3I RS485 230-240V TRANSDUCER / ENERGY ANALYZER

Cod. PFA7481-02

DC energy transducer / analyzer suitable for measuring simultaneously 3 strings in the Photovoltaic systems. 3 x 60mV or 100mV current inputs for the shunts (not included - see Shunt section). Built in RS485 port. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply.



PFA7481-12  ATTO D4 DC 3I RS485 230-240V 1DI 2DO ENERGY ANALYZER


ATTO D4 DC 3I RS485 230-240V 1DI 2DO TRANSDUCER / ENERGY ANALYZER

Cod. PFA7481-12

DC energy transducer / analyzer suitable for measuring simultaneously 3 strings in the Photovoltaic systems. 3 x 60mV or 100mV current inputs for the shunts (not included - see Shunt section). Built in RS485 port, 1 digital input and 2 digital outputs. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply.



PFA74B1-02  ATTO D4 DC HALL RS485 230-240V

ATTO D4 DC HALL RS485 230-240V

Cod. PFA74B1-02

DC energy counter/analyzer. Measures voltage (max and min), current (max and min), power and energy. 4V input for a split current transformer of the Split CTS DC Mini Series DC (see Split CT Mini Series section). Built in RS485 port. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply.



PFA747H-02  ATTO D4 DC E-WI HI 230-240V TRANSDUCER / ANALYZER

ATTO D4 DC E-WI HI 230-240V TRANSDUCER / ENERGY ANALYZER

Cod. PFA747H-02

DC energy transfucer / analyzer suitable for photovoltaic or battery systems. 60mV or 100mV current input for the shunts (not included - see Shunt section). Built in RS485 port. Transceives the data via radio waves (wireless) using the E-Wi protocol. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply.



PFAQ280-00  VOLTAGE DIVIDER D2 DC 900V/300V

VOLTAGE DIVIDER D2 DC 900V/300V

Cod. PFAQ280-00

Voltage divider for FEMTO DC and ATTO DC up to 900 V. 3:1 ratio. 2 DIN modules size.



PFC0551-2  DC D2 230V 1 CHANNEL SPLIT CORE CURRENT CONVERTER



1 channel current converter for using the Electrex instruments of the DC Hall series, paired with the Split CTS Mini Series DC,  for measuring  DC current.  Allows interfacing between the measuring instrument and Split CTS Series Mini DC that are powered by the converter, through which the signal is conditioned and normalized for the reading by the measuring instrument. DIN rail mount type, 2 DIN modules size. 230-240 Vac power supply.


SHUNT  DERIVATORI DI CORRENTE (SHUNT)

VOLTAGE DROP (SHUNT)

Cod. SHUNT

0,5 % class. 60MV voltage drop. 10A and 25A version are provided with a plastic socket. All models are conform to the DIN 43703 standard. Ideal to be used with the instruments Femto D4 DC and Atto D4 DC.


CONTACTS

export.electrex.akse

Tel: +39 0522 924244

Fax: +39 0522 924245

export@electrex.it

 
Banner

Newsletter

Enter your email address to have Electrex news, special offers and product announcements delivered directly to your inbox.

Name & Surname *
Country *
Email *


Companies using our solutions:

Electrex is a brand of Akse s.r.l. - Via Aldo Moro, 39 - Reggio Emilia - Italy - Tel: +39 0522 924244 Fax: +39 0522 924245 - VAT IT01544980350 - info@electrex.it
Joomla! is Free Software released under the GNU/GPL License.