FEMTO D4 RS485 230-240V ENERGY ANALYZER LCD display. DIN rail mount 4 modules. RS485 port. 230-240V Power supply. |
||
|
|
FEMTO D4 RS485 230-240V 1DI 2DO ENERGY ANALYZER LCD display. DIN rail mount 4 modules. RS485 port, 1 Digital Input, 2 Digital Outputs. 230-240V Power supply. |
||
|
|
|
FEMTO D4 70A RS485 230-240V ENERGY ANALYZER LCD display. DIN rail mount 4 modules. RS485 port, 1 Digital Input, 2 Digital Outputs. 70 A direct input via external CTs (1 included). 230-240V Power supply. |
|
|
|
FEMTO D4 70A RS485 230-240V 1DI 2DO ENERGY ANALYZER LCD display. DIN rail mount 4 modules. RS485 port, 1 Digital Input, 2 Digital Outputs. 70 A direct input via external CTs (1 included),1 Digital Input, 2 Digital Outputs. 230-240V Power supply. |
||
![]() |
FEMTO D4 70A RS485 230-240V 1DI 2DO SELF POWERED ENERGY ANALYZER LCD display designed for special TA Electrex 70A (1 included in the package). RS485 port. 1 Digital input and 2 Digital outputs. |
||
![]() |
FEMTO D4 3I 70A RS485 230-240V ENERGY ANALYZER Energy transfucer / analyzer suitable for measuring up to 3 mono phases (6 kW max. each). |
||
![]() |
Encapsulated 70A CT for FEMTO D4 70A meters. 9mm hole diameter. |
||
![]() |
FEMTO D4 RS485 230-240V 2AO4-20mA ENERGY ANALYZER LCD display. DIN rail mount 4 modules. RS485 port, 2 passive 4-20mA analogue outputs. 230-240V Power supply. |
||
![]() |
FEMTO D4 RS485 230-240V 1DI 2DO SELF POWERED ENERGY ANALYZER LCD display. DIN rail mount 4 modules. RS485 port, 1 Digital Input and 2 Digital Outputs self powered. 230-240V Power supply. |
||
![]() |
FEMTO D4 DC RS485 230-240V 1DI 2DO ENERGY ANALYZER LCD display. DIN rail mount 4 modules. RS485 port, 1 Digital Input, 2 Digital Outputs. 230-240 V Power supply. |
||
![]() |
FEMTO D4 DC RS485 18÷60VDC 1DI 2DO ENERGY ANALYZER LCD display. DIN rail mount 4 modules. RS485 port, 1 Digital Input and 2 Digital Outputs self powered. 18÷60Vdc Power supply. |
||
![]() |
VOLTAGE DIVIDER D2 DC 900V/300V Voltage divider for FEMTO DC and ATTO DC up to 900 V. 3:1 ratio. 2 DIN modules size. |
||
![]() |
FEMTO D4 E-WI HI 230-240V ENERGY ANALYZER Transducer / analyzer with backlighted LCD graphic display. Built-in RS485 serial port (Modbus protocol). Transceives the data via radio waves (wireless) using the E-Wi protocol. DIN rail mount type, size 4 DIN modules (D4). Power supply 230-240Vac. |
||
![]() |
FEMTO D4 70A E-WI HI 230-240V ENERGY ANALYZER Transducer / analyzer with backlighted LCD graphic display. Suitable with external CT 70A cod. PFAE000-00 (1 already supplied and included in the packaging). Built-in RS485 serial port (Modbus protocol). Transceives the data via radio waves (wireless) using the E-Wi protocol. DIN rail mount type, size 4 DIN modules (D4). Power supply 230-240Vac. |
||
![]() |
FEMTO D4 DC E-WI HI 230-240V ENERGY ANALYZER DC energy transducer / analyzer suitable for photovoltaic or battery systems with backlighted LCD graphic display. Built in RS485 port. Transceives the data via radio waves (wireless) using the E-Wi protocol. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply. |
||
![]() |
FEMTO 96 RS485 230-240V ENERGY ANALYZER LCD display. Flush mount type (96 x 96 mm.). RS485 port. 230-240V Power supply. |
||
![]() |
FEMTO 96 RS485 230-240V 1DI 2DO ENERGY ANALYZER LCD display. Flush mount type (96 x 96 mm.). RS485 port, 1 Digital Input, 2 Digital Outputs. 230-240V Power supply. |
||
![]() |
FEMTO 96 RS485 230-240V 2AO4-20mA ENERGY ANALYZER LCD display. Flush mount type (96 x 96 mm). RS485 port, 2 passive 4-20mA analogue outputs. 230-240V Power supply. |
||
![]() |
FEMTO 96 E-WI HI 230-240V ENERGY ANALYZER Transducer / analyzer with backlighted LCD graphic display. Built-in RS485 serial port (Modbus protocol). Transceives the data via radio waves (wireless) using the E-Wi protocol. Flush mount type, size 96x96 mm. Power supply 230-240Vac. |
||
![]() |
ETTO D2 230-240V ENERGY COUNTER Electrical energy counter with pulse output. Etto can be sealed with a tamper proof kit provided with the instrument. Performs the measure of the active energy on a single phase network with direct connection up to 32A. |
||
![]() |
PLUS 96 Y RS485 230V ENERGY ANALYZER This is a discontinued product substituted by FEMTO 96 cod. PFA6C11-02. |
||
![]() |
PLUS D6 RS485 230V ENERGY ANALYZER This is a discontinued product substituted by FEMTO D4 cod. PFA6411-02. |
||
![]() |
MICO DOMO ENERGY AND POWER METER This is a discontinued product substituted by FEMTO D4 70A cod. PFA6431-12. |
||
![]() |
MICO3-P ENERGY AND POWER METER This is a discontinued product substituted by FEMTO D4 1DI 2DO cod. PFA6411-12. |
||
![]() |
MICO3-485 ENERGY AND POWER METER This is a discontinued product substituted by FEMTO D4 cod. PFA6411-02. |
||
![]() |
MICO3-485 2T ENERGY AND POWER METER This is a discontinued product substituted by FEMTO D4 RS485 230-240V 1DI 2DO SELF-POWERED cod. PFA6411-E2. |
||
![]() |
MICO3-485 70 230V ENERGY AND POWER METER This is a discontinued product substituted by FEMTO D4 70A cod. PFA6431-12 (più 2 PFAE000-00). |
||
![]() |
This is a discontinued product substituted by ETTO D2 cod. PFAA280-C2. |
||
![]() |
For an alternative instrument, please contact Electrex. |
| X3M D6 85÷265V ENERGY DATA MANAGER Cod. PFE840-00 |
|
LCD display. DIN rail mount 6 modules. 85-265Vac/100-374Vdc power supply |
CONTACTS
Energy Meters - Energy Analyzers
Analyzer, counter and multimeter extremely versatile and precise designed to meet the more sophisticated applications of monitoring of the electrical parameters and management of consumption of electricity in the civil, commercial and industrial sector.
A specific version of the Femto has been designed for the measure in direct current, for example in applications in the context of photovoltaic systems.
Versatility - Only one instrument for every kind of insertion. In fact the Femto is suitable for application over all types of electric grid, single, bi phase or tri-phase with 3 or 4 wire, symmetric or asymmetric, balanced or unbalanced, low or medium tension; with 1, 2 or 3 CT.
Digital input and outputs / alarms - Femto is equipped by series of 1 input and 2 digital outputs optically insulated. The input is used to count signals of external pulses (e.g. gas counters, water, pieces, etc.), or to detect the state (e.g. ON/OFF in machines, switches, etc.). While the 2 outputs may transmit pulses proportional to the active and reactive energy (e.g. for PLC), internal alarms or can be used as units of output controlled remotely.
Readings: precision and reliability - Over 60 True-RMS value readings on 2 and 4 quadrant (import/ export), up to the 31st harmonics. Maximum precision also in the presence of quickly variable loads (e.g. spot welders).