Banner


PFNY6-00509-100 YOCTO NET D6 WEB 85÷265V WEB DATA MANAGER

YOCTO NET D6 WEB 85÷265V WEB DATA MANAGER

Cod. PFNY6-00509-100

Network bridge between the Ethernet network (Modbus TCP/IP protocol) and the RS485 line (Modbus RTU protocol) for communication and data collection of Electrex devices. FSTN graphic display. Modbus-TCP Server (max. 4 simultaneous connections). Astronomical and perpetual clock/calendar, battery powered and non-volatile, industrial type memory. Remote firmware update. Built-in WEB Server including Upgrade Web option: standard web pages for real-time measures displaying. Other functions can be activated via firmware upgrade (PUK entry). FTP Server. ExpBus, high speed communication, port for external devices (inputs and outputs modules, and environmental sensors). Equipped with NFC technology. DIN rail mount 6 modules. Wide range power supply 85÷265V/100÷374VDC.



PFNY6-005Q9-110	YOCTO NET D6 WEB LOG 8 85÷265V 2DI 2DO WEB DATA MANAGER

YOCTO NET D6 WEB LOG 8 85÷265V 2DI 2DO WEB DATA MANAGER

Cod. PFNY6-005Q9-110

Network bridge between the Ethernet network (Modbus TCP/IP protocol) and the RS485 line (Modbus RTU protocol) for communication and data-logging of Electrex devices. FSTN graphic display. Modbus-TCP Server (max. 4 simultaneous connections). Astronomical and perpetual clock/calendar, battery powered and non-volatile, industrial type memory. Remote firmware update. Built-in WEB Server including Upgrade Web option: standard web pages for real-time measures displaying. Already activated one Log 8 logging service (log of 8 Electrex instruments/Modbus registers, power / energy and digital inputs). Other functions can be activated via firmware upgrade (PUK entry). FTP Server. 2 digital inputs and 2 digital outputs. ExpBus, high speed communication, port for external devices (inputs and outputs modules, and environmental sensors). Equipped with NFC technology. DIN rail mount 6 modules. Wide range power supply 85÷265V/100÷374VDC.



PFNY6-005Q9-F10  YOCTO NET D6 WEB LOG 8 FULL 85÷265V 2DI 2DO WEB DATA MANAGER

YOCTO NET WI-FI EDA D6 WEB LOG 8 85-265V 2DI 2DO WEB DATA MANAGER

Cod. PFNY6-00AQ9-110

Network bridge between the Ethernet and/or Wi-Fi network (Modbus TCP/IP protocol) and the RS485 line (Modbus RTU protocol) for communication and data-logging of Electrex devices. Wi-Fi connection via external antenna cod. PFC3530 (included); compliant with IEEE 802.11b/g/n. FSTN graphic display. Modbus-TCP Server (max. 4 simultaneous connections). Astronomical and perpetual clock/calendar, battery powered and non-volatile, industrial type memory. Remote firmware update. Built-in WEB Server including Upgrade Web option: standard web pages for real-time measures displaying. Already activated one Log 8 logging service (log of 8 Electrex instruments/Modbus registers, power / energy and digital inputs). Other functions can be activated via firmware upgrade (PUK entry). FTP Server. 2 digital inputs and 2 digital outputs. ExpBus, high speed communication, port for external devices (inputs and outputs modules, and environmental sensors). Equipped with NFC technology. DIN rail mount 6 modules. Wide range power supply 85÷265V/100÷374VDC.


PFNY6-005Q9-F10  YOCTO NET D6 WEB LOG 8 FULL 85÷265V 2DI 2DO WEB DATA MANAGER

YOCTO NET D6 WEB LOG 8 FULL 85÷265V 2DI 2DO WEB DATA MANAGER

Cod. PFNY6-005Q9-F10

Network bridge between the Ethernet network (Modbus TCP/IP protocol) and the RS485 line (Modbus RTU protocol) for communication and data-logging of Electrex devices. FSTN graphic display. Modbus-TCP Server (max. 4 simultaneous connections). Astronomical and perpetual clock/calendar, battery powered and non-volatile, industrial type memory. Remote firmware update. Built-in WEB Server including Upgrade Web option: standard web pages for real-time measures displaying. Already activated one Log 8 logging service (log of 8 Electrex instruments/Modbus registers, power / energy and digital inputs), Upgrade Charts for historical data displaying on graphs, Upgrade Energy Automation, E-Mail/Sms and Calendars. FTP Server. 2 digital inputs and 2 digital outputs. ExpBus, high speed communication, port for external devices (inputs and outputs modules, and environmental sensors). Equipped with NFC technology. DIN rail mount 6 modules. Wide range power supply 85÷265V/100÷374VDC.


PFNY6-005Q9-F10  YOCTO NET D6 WEB LOG 8 FULL 85÷265V 2DI 2DO WEB DATA MANAGER

YOCTO NET D6 WEB LOG 40 85÷265V 2DI 2DO WEB DATA MANAGER

Cod. PFNY6-005Q9-150

Network bridge between the Ethernet network (Modbus TCP/IP protocol) and the RS485 line (Modbus RTU protocol) for communication and data-logging of Electrex devices. FSTN graphic display. Modbus-TCP Server (max. 4 simultaneous connections). Astronomical and perpetual clock/calendar, battery powered and non-volatile, industrial type memory. Remote firmware update. Built-in WEB Server including Upgrade Web option: standard web pages for real-time measures displaying. Already activated 5 x Log 8 logging service (log of 39 Electrex instruments/Modbus registers, power / energy and digital inputs). Other functions can be activated via firmware upgrade (PUK entry). FTP Server. 2 digital inputs and 2 digital outputs. ExpBus, high speed communication, port for external devices (inputs and outputs modules, and environmental sensors). Equipped with NFC technology. DIN rail mount 6 modules. Wide range power supply 85÷265V/100÷374VDC.


PFSU940-86  NET UPGRADE NET TO MASTER VERSION (PUK)



Software implementation through PUK code. Transforms the Kilo Net, Exa net, Femto ECT Net and Femto 25A D Net in the Master version. The Master version allows to communicate with all the Electrex devices connected to the same Ethernet network.


PFSU940-01 NET UPGRADE LOG 8 (PUK)


Software implementation through PUK code. Adds 1 storage service, Log 8, to the Kilo net, Exa net, Femto ECT net, Femto 25A D Net and Yocto net D6 product families. It is possible to manage up to a maximum of 8 storage services for each device.


PFSU940-02 NET UPGRADE LOG 16 (PUK)



Software implementation through PUK code. Doubbles the capacity of the storage services from Log 8  to Log 16. Available for the Kilo net log and Yocto net D6 log only.



PFSU940-10 NET UPGRADE WEB OPEN (PUK)



Software implementation through PUK code. Adds to the product families Kilo net, Exa net, Femto ECT net, Femto 25A D Net and Yocto net D6 the possibility to create custom web pages.


PFSU940-30 NET UPGRADE CHARTS (PUK)



Software implementation through PUK code. Allows  to display on a web page charts, with configurable intervals, of electricity, temperature, humidity, luminosity, etc. obtained from the files stored in the Kilo net, Exa net, Femto ECT net, Femto 25A D Net and Yocto net D6 with the possibility to export to CSV files.


PFSU940-25 NET UPGRADE 4YOU (PUK)



Software implementation through PUK code. Allows to modify an existing logging service Log 8 in the Kilo net log (on request for the Exa net log, Femto ECT net log, Femto 25A D net log and Yocto net D6 log). For example for running measurement campaigns and / or increase / decrease the sampling frequency and the number of days logged.


PFSU940-15 NET UPGRADE MAIL ALARM (PUK)



Software implementation through PUK code entry. Adds to the product families Kilo net, Exa net, Femto ECT net, Femto 25A D net and Yocto net D6 the ability to send email notifications/alarms related to parameters measured from the device (Modbus registers or input status). In the Net version of the devices, using the  upgrade Energy Automation, it is possible to extend this functionality also for parameters retrieved from devices connected in a sub network via Rs485.


PFSU940-20 NET UPGRADE CALENDAR (PUK)


Software implementation through PUK code entry. Adds to the product families Kilo net, Exa net, Femto ECT net, Femto 25A D net and Yocto net D6 the ability to send SMS notifications/alarms related to parameters measured from the device (Modbus registers or input status). Router Wi-Fi UMTS cod. PFC3510 with data SIM needed. In the Net version of the devices, using the  upgrade Energy Automation, it is possible to extend this functionality also for parameters retrieved from devices connected in a sub network via Rs485.



PFSU940-20 NET UPGRADE CALENDAR (PUK)



Software implementation through PUK code entry. Allows to program, via the web interface of the Kilo net (on request also for Exa net, Femto ECT net, Femto 25A D net and Yocto net D6) Energy Automation applications  for simple or complex taks such as ON/OFF switching, alarms/notifications and automations conditioned  from events in order to assure a higher energy efficiency of the systems. Adding the Calendars upgrade it ispossible to schedule the automation tasks using customizable calendars. While adding the email / SMS upgrade it is possible to integrate also the sending of e-mail and/or SMS.


PFSU940-20 NET UPGRADE CALENDAR (PUK)



Software implementation through PUK code. Adds to the Kilo net, Exa net, Femto ECT net, Femto 25A D net and Yocto net D6 the ability to manage Energy Automation functions such as on / off switches, alarms / alerts and automatisms conditioned to events and / or an annual calendar configurable in minutes / hours / days / months.


PFSU940-20 NET UPGRADE CALENDAR (PUK)



Bundle including the software implementations (PUK): cod. PFSU940-16 Net Upgrade Energy Automation, PFSU940-20 Net Upgrade Calendars and PFSU940-15 Net Upgrade email.


PFSU940-20 NET UPGRADE CALENDAR (PUK)



Bundle including the software implementations (PUK): cod. PFSU940-16 Net Upgrade Energy Automation, PFSU940-20 Net Upgrade Calendars, PFSU940-15 Net Upgrade email and PFSU940-17 Net Upgrade SMS.


PFSU940-20 NET UPGRADE CALENDAR (PUK)



Software implementation through PUK code entry. Adds to the product families Kilo net, Exa net, Femto ECT net, Femto 25A D net and Yocto net D6 the possibility to send / push and save into a remote FTP server an Xml standard file (customizable on request) containing data stored in the log services. Adding the PUK Energy Automation it is possible to relate the sending of the file with also complex events/scenarios.


PFSU940-40 NET UPGRADE NEW FEATURES



Upgrade to the new firmware versions of Kilo net, Exa net, Femto ECT net, Femto 25A D net and Yocto net D6 adding new features to the instruments.


PFA94D3-97  YOCTO NET WEB D4 9÷36V 2DI 2DO NETWORK BRIDGE

YOCTO NET WEB D4 15÷36V 2DI 2DO NETWORK BRIDGE

Cod. PFA94D3-97

Network bridge between the Ethernet port and Modbus ports used to communicate with the Electrex instruments via RS485 and TTL. Including the WEB Upgrade option PFSW940-05. LCD backlit graphic display. 2 digital inputs and 2 digital outputs. DIN rail mount 4 modules. Power supply 15÷36Vac / 18÷60Vdc.



PFA94D3-99  YOCTO NET WEB LOG 8 MAIL CALENDAR CHARTS D4 15÷36V 2DI 2DO NETWORK BRIDGE

YOCTO NET WEB LOG 8 MAIL CALENDAR CHARTS D4 15÷36V 2DI 2DO NETWORK BRIDGE

Cod. PFA94D3-99

Network bridge between the Ethernet port and Modbus ports used to communicate with the Electrex instruments via RS485 and TTL. Including the WEB Upgrade option PFSW940-05, PFSW940-01 Upgrade Log 8, PFSW940-15 Upgrade Mail Alarm, PFSW940-20 Upgrade Calendar, PFSW940-30 Upgrade Charts. LCD backlit graphic display. 2 digital inputs and 2 digital outputs. DIN rail mount 4 modules. Power supply 15÷36Vac / 18÷60Vdc.



PFA94D4-57  YOCTO NET WEB LOG 40 D4 15÷36V 2DI 2DO NETWORK BRIDGE DATA LOGGER

YOCTO NET WEB LOG 40 D4 15÷36V 2DI 2DO NETWORK BRIDGE DATA LOGGER

Cod. PFA94D4-57

Network bridge between the Ethernet port and Modbus ports used to communicate with the Electrex instruments via RS485 and TTL. Includes the WEB Upgrade option PFSW940-05. LCD backlit graphic display. 2 digital inputs and 2 digital outputs. 5 storage services (e.g. log of powers and energies only in import from 40 Electrex instruments). DIN rail mount 4 modules. Power supply 15÷36Vac / 18÷60Vdc or taken from an X3M or FLASH through a cable (code PCAFL00-00).


PFA94D4-97  YOCTO NET WEB MASTER D4 15÷36V 2DI 2DO NETWORK BRIDGE

YOCTO NET WEB MASTER D4 15÷36V 2DI 2DO NETWORK BRIDGE

Cod. PFA94D4-97

Network bridge for the supervision of Electrex instruments connected to the Ethernet network. Includes PFSW940-05 Upgrade Web option. Expandible options via PUK code entry Upgrade (Puk). LCD backlit graphic display. 2 digital inputs and 2 digital outputs. Size 4 DIN modules. 15÷36 vac / 18÷60 Vdc power supply.



PFA94D4-99  YOCTO NET MASTER LOG 8 D4 FULL 15÷36V 2DI 2D NETWORK BRIDGE

YOCTO NET MASTER LOG 8 D4 FULL 15÷36V 2DI 2D NETWORK BRIDGE

Cod. PFA94D4-99

Network bridge for the supervision and for sending email alerts (and SMS if connected to one Yocto Gate Master) collected by all the Electrex instruments connected to the Ethernet network . Includes PFSW940-05 Upgrade Web, PFSW940-01 Upgrade Log 8, PFSW940-15 Upgrade Mail Alarm, PFSW940-20 Upgrade Calendar, PFSW940-30 Upgrade Charts options.  LCD backlit graphic display. 2 digital inputs and 2 digital outputs. Size 4 DIN modules. 15÷36 vac / 18÷60 Vdc power supply.



PFA94DH-97  YOCTO NET COORDINATOR WEB HI D4 E-WI 9÷36V 2DI 2DO NET. BR.

YOCTO NET COORDINATOR WEB HI D4 E-WI 15÷36V 2DI 2DO NET. BR.

Cod. PFA94DH-97

Coordinator node of the E-Wi wireless network including PFSW940-05 Upgrade Web option. Network bridge between the Ethernet port and Modbus ports used to communicate with the Electrex instruments via RS485 and TTL. LCD backlit graphic display. 2 digital inputs and 2 digital outputs. DIN rail mount 4 modules. Power supply 15÷36Vac / 18÷60Vdc.



PFA94DH-17 YOCTO NET WEB ROUTER D4 E-WI HI 15÷36V 2DI 2DO NETWORK BRIDGE

YOCTO NET WEB ROUTER D4 E-WI HI 15÷36V 2DI 2DO NETWORK BRIDGE

Cod. PFA94DH-17

Router node of the E-Wi wireless network including PFSW940-05 Upgrade Web option. Transcieves the data via radio waves at 250kbs and on 2.4GHz frequency rate. Acts as signal repeater. Network bridge between the Ethernet port and Modbus ports used to communicate with the Electrex instruments via RS485 and TTL. LCD backlit graphic display. 2 digital inputs and 2 digital outputs. Configuration and status control through web pages. DIN rail mount 4 modules. Power supply 15÷36Vac / 18÷60Vdc.



PFA94DH-22  YOCTO BRIDGE D4 E-WI HI 230-240V

YOCTO BRIDGE D4 E-WI HI 230-240V

Cod. PFA94DH-22

Bridge node of the E-Wi wireless network with not expandable functions. Transcieves the data via radio waves. Network bridge between the Ethernet port and Modbus ports used to communicate with the Electrex instruments via RS485. LCD backlit graphic display. DIN rail mount 4 modules. Power supply 230-240 Vac.



PFA94DH-99  YOCTO NET WEB COORDINATOR LOG 8 MAIL CALENDAR CHARTS D4 E-WI HI 15÷36V 2DI 2DO NETWORK BRIDGE

YOCTO NET WEB COORDINATOR LOG 8 MAIL CALENDAR CHARTS D4 E-WI HI 15÷36V 2DI 2DO NETWORK BRIDGE

Cod. PFA94DH-99

Coordinator node of the E-Wi wireless network including PFSW940-05 Upgrade Web, PFSW940-01 Upgrade Log 8, PFSW940-15 Upgrade Mail Alarm, PFSW940-20 Upgrade Calendar, PFSW940-30 Upgrade Charts options. Transcieves the data via radio waves at 250kbs and on 2.4GHz frequency rate. Network bridge between the Ethernet port and Modbus ports. LCD backlit graphic  display. 2 digital inputs and 2 digital outputs. DIN rail mount 4 modules. Power supply 15÷36Vac / 18÷60Vdc.



PFATU0H-0C  DECA ROUTER E-WI 5V

DECA ROUTER E-WI 5V

Cod. PFATU0H-0C

Router of the E-Wi protocol based wireless network. Transcieves the data via radio waves to the Coordinator at 250kbs and on 2.4GHz frequency rate. Serves as a Repeater of the E-Wi signal.



PFA94DA-07 YOCTO NET COORDINATOR WEB D4 E-WI EDA 15÷36V 2DI 2DO NETWORK BRIDGE

YOCTO NET WEB COORDINATOR D4 E-WI EDA 15÷36V 2DI 2DO NETWORK BRIDGE

Cod. PFA94DA-07

Coordinator node of the E-Wi wireless network equipped with external antenna connector (PFC3530 or PFC3533, not included). Transcieves the data via radio waves at 250kbs and on 2.4GHz frequency rate. Network bridge between the Ethernet port and Modbus ports used to communicate and retrieve data from the Electrex instruments via RS485 and TTL port. LCD backlit graphic  display. 2 digital inputs and 2digital outputs. Configuration via WEB pages. DIN rail mount 4 modules. Power supply 15÷36Vac / 18÷60Vdc.



PFA94DA-17 YOCTO NET ROUTER WEB D4 E-WI EDA 15÷36V 2DI 2DO

YOCTO NET WEB ROUTER D4 E-WI EDA 15÷36V 2DI 2DO

Cod. PFA94DA-17

Router node, with expandable features, of the E-Wi wireless network equipped with external antenna connector (PFC3530 o PFC3533, not included). Transcieves the data to the Coordinator node via radio waves at 250kbs and on 2.4GHz frequency rate. Serves as a Repeater of the E-Wi signal. Network bridge between the Ethernet port and Modbus ports used to communicate and retrieve data from the Electrex instruments via RS485 and TTL port. LCD backlit graphic  display. 2 digital inputs and 2digital outputs. Configuration via WEB pages. DIN rail mount 4 modules. Power supply 15÷36Vac / 18÷60Vdc.


PFA94DA-22  YOCTO BRIDGE D4 E-WI EDA 230-240V

YOCTO BRIDGE D4 E-WI EDA 230-240V

Cod. PFA94DA-22

Bridge node of the E-Wi wireless network equipped with external antenna connector. Transcieves the data via radio waves to the Coordinator. Network bridge between the Ethernet port and Modbus ports used to communicate and retrieve data from the Electrex instruments via RS485. 230-240V power supply.


PFA94D4-96 YOCTO NET MASTER D4 9÷36V 2DI 2DO NETWORK BRIDGE

YOCTO NET MASTER D4 15÷36V 2DI 2DO NETWORK BRIDGE

Cod. PFA94D4-96

Network bridge for the supervision and for sending email alerts (and SMS if connected to one yocto Gate) collected by all the Electrex power meters. LCD backlit graphic display. 2 digital inputs and 2 digital outputs. Size 4 DIN modules. 15÷36 vac / 18÷60 vdc power supply.



PFA94DH-06  YOCTO NET COORDINATOR D4 E-WI HI 9÷36V 2DI 2DO

YOCTO NET COORDINATOR D4 E-WI HI 15÷36V 2DI 2DO

Cod. PFA94DH-06

Coordinator node of the E-Wi protocol wireless network. Transcieves the data via radio waves. Network bridge between the Ethernet port and Modbus ports used to communicate with the Electrex instruments via RS485 and TTL. LCD backlit graphic display. 2 digital inputs and 2 digital outputs. DIN rail mount 4 modules. Power supply 15÷36Vac / 18÷60Vdc.



PFA94DH-16  YOCTO NET ROUTER D4 E-WI HI 9÷36V 2DI 2DO

YOCTO NET ROUTER D4 E-WI HI 15÷36V 2DI 2DO

Cod. PFA94DH-16

Router node of the E-Wi protocol wireless network with expandable functions. Transcieves the data via radio waves. Network bridge between the Ethernet port and Modbus ports used to communicate with the Electrex instruments via RS485 and TTL. LCD backlit graphic display. 2 digital inputs and 2 digital outputs. DIN rail mount 4 modules. Power supply 15÷36Vac / 18÷60Vdc.



PFA94DH-98  YOCTO NET COOR. WEB LOG 8 MAIL CAL. D4 E-WI HI 9÷36V 2DI 2DO NET. BR.

YOCTO NET COOR. WEB LOG 8 MAIL CAL. D4 E-WI HI 15÷36V 2DI 2DO NET. BR.

Cod. PFA94DH-98

Coordinator node of the E-Wi wireless network including PFSW940-05 Upgrade Web, PFSW940-01 Upgrade Log 8, PFSW940-15 Upgrade Mail Alarm, PFSW940-20 Upgrade Calendar options. Transcieves the data via radio waves. Network bridge between the Ethernet port and Modbus ports. LCD backlit graphic display. 2 digital inputs and 2digital outputs. DIN rail mount 4 modules. Power supply 15÷36Vac / 18÷60Vdc.



PFA94DA-06  YOCTO NET COORDINATOR D4 E-WI EDA 15÷36V 2DI 2DO

YOCTO NET COORDINATOR D4 E-WI EDA 15÷36V 2DI 2DO

Cod. PFA94DA-06

Coordinator node of the E-Wi wireless network equipped with external antenna connector. Transcieves the data via radio waves. Network bridge between the Ethernet port and Modbus ports used to communicate and retrieve data from the Electrex instruments via RS485.



PFA94DA-16  YOCTO NET ROUTER D4 E-WI EDA 15÷36V 2DI 2DO

YOCTO NET ROUTER D4 E-WI EDA 15÷36V 2DI 2DO

Cod. PFA94DA-16

Router node of the E-Wi wireless network equipped with external antenna connector. Transcieves the data via radio waves serving also as a signal Repeater. Network bridge between the Ethernet port and Modbus ports used to communicate and retrieve data from the Electrex instruments via RS485 and TTL port.


PFSW940-01  YOCTO NET UPGRADE LOG 8 (PUK)

YOCTO NET UPGRADE LOG 8 (PUK)

Cod. PFSW940-01

Performed by field PUK code entry, it adds 1 storage service to the Yocto Net and to the Yocto Net Log (e.g. log of powers and energies only in import from 8 different Electrex power meters).



PFSW940-05  YOCTO NET UPGRADE WEB (PUK)

YOCTO NET UPGRADE WEB (PUK)

Cod. PFSW940-05

Performed by field PUK code entry. It adds to the Yocto Net and to the Yocto Net Log a web server with the possibility to show into standard web pages the readings gathered from the various Electrex sub-meters.



PFSW940-10  YOCTO NET UPGRADE WEB OPEN (PUK)

YOCTO NET UPGRADE WEB OPEN (PUK)

Cod. PFSW940-10

Performed by field PUK code entry. It adds to the Yocto Net and to the Yocto Net Log a open web server with the possibility to upload customized web pages. The Yocto Net Upgrade Web (code PFSW940-05) is requested for this option.



PFSW940-15  YOCTO NET UPGRADE MAIL ALARM (PUK)

YOCTO NET UPGRADE MAIL ALARM (PUK)

Cod. PFSW940-15

Performed by field PUK code entry. It adds to the Yocto Net and to the Yocto Net Log the possibility to send e-mail with various user programmable alarms and alerts (and SMS if connected to a Yocto Gate).



PFSW940-20  YOCTO NET UPGRADE CALENDAR (PUK)

YOCTO NET UPGRADE CALENDAR (PUK)

Cod. PFSW940-20

Software implementation using PUK code. Adds to the Yocto Net and the Yocto Net Log the ability to manage functions of Energy Automation based on a calendar.



PFSW940-30 YOCTO NET UPGRADE CHARTS (PUK)

YOCTO NET UPGRADE CHARTS (PUK)

Cod. PFSW940-30

Performed by field PUK code entry. It allows to display on an HTML WEB page, the daily charts of electrical energy, temperature, humidity, luminosity, etc. retrieving the data from the logging files of the Yocto Net log.



PFSW940-25  YOCTO NET UPGRADE 4YOU (PUK)

YOCTO NET UPGRADE 4YOU (PUK)

Cod. PFSW940-25

Performed by field PUK code entry. It allows, through a memory optimizer, to modify the existing log & storage services of a Yocto Net Log. Every Yocto Net can handle up to 5 different services.



PFSW940-31  YOCTO NET UPGRADE BUNDLE WEB, LOG 8, MAIL ALARM, CALENDAR, CHARTS (PUK)

YOCTO NET UPGRADE BUNDLE WEB, LOG 8, MAIL ALARM, CALENDAR, CHARTS (PUK)

Cod. PFSW940-31

Bundle software including the options cod. PFSW940-05 Upgrade Web, cod. PFSW940-01 Upgrade Log 8, cod. PFSW940-15 Upgrade Mail Alarm, cod. PFSW940-20 Upgrade Calendar and cod. PFSW940-30 Upgrade Charts.



PFSW940-35  YOCTO NET UPGRADE MASTER (PUK)

YOCTO NET UPGRADE MASTER (PUK)

Cod. PFSW940-35

Software implementation via PUK. Transforms the Yocto Net in Yocto net Master. The Master version permits to communicate with all the Electrex devices connected to the same Ethernet network.



PFSW940-40 YOCTO NET UPGRADE NEW FEATURES

YOCTO NET UPGRADE NEW FEATURES

Cod. PFSW940-40

Firmware upgrade to the last version available for the Yocto Net, adding new features to the instrument.



PCAFL00-00   	 POWER CABLE YOCTO NET / X3M D6 - FLASH D6

POWER CABLE YOCTO NET / X3M D6 - FLASH D6

Cod. PCAFL00-00

TTL cable that allows to feed the Yocto Net through the instruments X3M D6 and FLASH D6.



PFA9409-06  YOCTO GATE D4 8÷32V GSM GATEWAY

YOCTO GATE D4 8÷32V GSM GATEWAY

Cod. PFA9409-06

Multifunctional gateway. 4 inputs, 4 outputs, 1 RS485 serial port. Built in GSM modem. Independent supervision of alarms of RS485 sub meters network.




PFA9409-96  YOCTO GATE MASTER D4 8÷32V GSM GATEWAY

YOCTO GATE MASTER D4 8÷32V GSM GATEWAY

Cod. PFA9409-96

Multifunctional gateway. 4 inputs, 4 outputs, 1 RS485 serial port. Built in GSM modem. Independent supervision of alarms of all RS485 sub meters network.



Companies using our solutions:

CONTACTS

export.electrex.akse

Tel: +39 0522 924244

Fax: +39 0522 924245

export@electrex.it

 

Newsletter

Enter your email address to have Electrex news, special offers and product announcements delivered directly to your inbox.

Name & Surname *
Country *
Email *


Banner
Electrex is a brand of Akse s.r.l. - Via Aldo Moro, 39 - Reggio Emilia - Italy - Tel: +39 0522 924244 Fax: +39 0522 924245 - VAT IT01544980350 - info@electrex.it
Joomla! is Free Software released under the GNU/GPL License.