Banner


PFAB201-N5P RS485 MODULE D2 24VDC 4DI 4DO

RS485 MODULE D2 24VDC 4DI 4DO

Cod. PFAB201-N5P

4 digital inputs and 4 digital outputs module suitable for an RS485 Electrex network. Requires a Gateway / Datalogger (e.g. Kilo net, Exa net, Femto ECT net or Yocto net) for data synchronisation and profile recording. DIN rail mount 2 modules. External power supply 24 Vdc needed (we recommend to use the switching power supply cod. PFTP100-Q2).



PFAB201-Q56 RS485 MODULE D2 24VDC 2DI 2DO 2AO4-20mA

RS485 MODULE D2 24VDC 2DI 2DO 2AO4-20mA

Cod. PFAB201-Q56

2 digital inputs, 2 digital outputs and 2 analog outputs 4-20mA module suitable for an RS485 Electrex network. Requires a Gateway / Datalogger (e.g. Kilo net, Exa net, Femto ECT net or Yocto net) for data synchronisation and profile recording. DIN rail mount 2 modules. External power supply 24 Vdc needed (we recommend to use the switching power supply cod. PFTP100-Q2).


PFAB201-R5Q RS485 MODULE D2 24VDC 4AI 2DI 2DO

RS485 MODULE D2 24VDC 4AI 2DI 2DO

Cod. PFAB201-R5Q

4 analog inputs, 2 digital inputs and 2 digital outputs module suitable for an RS485 Electrex network. Requires a Gateway / Datalogger (e.g. Kilo net, Exa net, Femto ECT net or Yocto net) for data synchronisation and profile recording. DIN rail mount 2 modules. External power supply 24 Vdc needed (we recommend to use the switching power supply cod. PFTP100-Q2).


PFAB201-T5Q  RS485 MODULE D2 24VDC I2C 2DI 2DO

RS485 MODULE D2 24VDC I2C 2DI 2DO

Cod. PFAB201-T5Q

I2C bus, 2 digital inputs and 2 digital outputs module suitable for an RS485 Electrex network. With I2C bus for connecting environmental sensors Deca Sensor Bus Unit Box (T, TH, TL, THL, THLB, L, B, up to 4 T). Requires a Gateway / Datalogger (e.g. Kilo net, Exa net, Femto ECT net or Yocto net) for data synchronisation and profile recording. DIN rail mount 2 modules. External power supply 24 Vdc needed (we recommend to use the switching power supply cod. PFTP100-Q2).


PFAB401-N2P RS485 MODULE D4 230-240V 4DI 4DO

RS485 MODULE D4 230-240V 4DI 4DO

Cod. PFAB401-N2P

4 digital inputs and 4 digital outputs module suitable for an RS485 Electrex network. Requires a Gateway / Datalogger (e.g. Kilo net, Exa net, Femto ECT net or Yocto net) for data synchronisation and profile recording. DIN rail mount 4 modules. Power supply 230-240Vac.


PFAB401-Q26 RS485 MODULE D4 230-240V 2DI 2DO 2AO4-20mA

RS485 MODULE D4 230-240V 2DI 2DO 2AO4-20mA

Cod. PFAB401-Q26

2 digital inputs, 2 digital outputs and 2 analog outputs 4-20mA module suitable for an RS485 Electrex network. Requires a Gateway / Datalogger (e.g. Kilo net, Exa net, Femto ECT net or Yocto net) for data synchronisation and profile recording. DIN rail mount 4 modules. Power supply 230-240Vac.


PFAB401-R2Q  RS485 MODULE D4 230-240V 4AI 2DI 2DO

RS485 MODULE D4 230-240V 4AI 2DI 2DO

Cod. PFAB401-R2Q

4 analog inputs, 2 digital inputs and 2 digital outputs module suitable for an RS485 Electrex network. Requires a Gateway / Datalogger (e.g. Kilo net, Exa net, Femto ECT net or Yocto net) for data synchronisation and profile recording. DIN rail mount 4 modules. Power supply 230-240Vac.



PFAB401-T2Q  RS485 MODULE D4 230-240V I2C 2DI 2DO

RS485 MODULE D4 230-240V I2C 2DI 2DO

Cod. PFAB401-T2Q

I2C bus, 2 digital inputs and 2 digital outputs module suitable for an RS485 Electrex network. With I2C bus for connecting environmental sensors Deca Sensor Bus Unit Box (T, TH, TL, THL, THLB, L, B, up to 4 T). Requires a Gateway / Datalogger (e.g. Kilo net, Exa net, Femto ECT net or Yocto net) for data synchronisation and profile recording. DIN rail mount 4 modules. Power supply 230-240Vac.


PFAB20E-N5P EXPBUS MODULE D2 24VDC 4DI 4DO



4 digital inputs and 4 digital outputs. Can be connected to Kilo D6, Exa Rj45 and Net, Femto ECT and Femto 25A D via the expansion bus ExpBus.



PFAB20E-N5P EXPBUS MODULE D2 24VDC 4DI 4DO



2 digital inputs, 2 digital outputs and 2 analog outputs 4-20mA module. Can be connected to Kilo D6, Exa Rj45 and Net, Femto ECT and Femto 25A D via the expansion bus ExpBus.



PFAB20E-R5Q  EXPBUS MODULE D2 24VDC 4AI 2DI 2DO



4 analog inputs, 2 digital inputs and 2 digital outputs  module. Can be connected to Kilo D6, Exa Rj45 and Net, Femto ECT and Femto 25A D via the expansion bus ExpBus.



PFAB20E-T5Q  EXPBUS MODULE D2 24VDC I2C 2DI 2DO



I2C bus, 2 digital inputs and 2 digital outputs module. With I2C bus for connecting environmental sensors Deca Sensor Bus Unit Box (T, TH, TL, THL, THLB, L, B, up to 4 T). Can be connected to Kilo D6, Exa Rj45 and Net, Femto ECT and Femto 25A D via the expansion bus ExpBus.



PFAB40E-N2P EXPBUS MODULE D4 230-240V 4DI 4DO



4 digital inputs and 4 digital outputs module. Can be connected to Kilo D6, Exa Rj45 and Net, Femto ECT and Femto 25A D via the expansion bus ExpBus.



PFAB40E-Q26 EXPBUS MODULE D4 230-240V 2DI 2DO 2AO4-20mA



2 digital inputs, 2 digital outputs and 2 analog outputs 4-20mA module. Can be connected to Kilo D6, Exa Rj45 and Net, Femto ECT and Femto 25A D via the expansion bus ExpBus.



PFAB40E-R2Q  EXPBUS MODULE D4 230-240V 4AI 2DI 2DO



4 analog inputs, 2 digital inputs and 2 digital outputs module. Can be connected to Kilo D6, Exa Rj45 and Net, Femto ECT and Femto 25A D via the expansion bus ExpBus.



PFAB40E-T2Q  EXPBUS MODULE D4 230-240V I2C 2DI 2DO



I2C bus, 2 digital inputs and 2 digital outputs module. With I2C bus for connecting environmental sensors Deca Sensor Bus Unit Box (T, TH, TL, THL, THLB, L, B, up to 4 T). Can be connected to Kilo D6, Exa Rj45 and Net, Femto ECT and Femto 25A D via the expansion bus ExpBus.



PFA9401-G6  YOCTO I-O D4 8÷32V 2AI 2DI 2RO 2DO INPUT-OUTPUT DEVICE

YOCTO I-O D4 8÷32V 2AI 2DI 2RO 2DO INPUT-OUTPUT DEVICE

Cod. PFA9401-G6

Multifunctional I/O device for RS485 networks. Built-in calendar/clock and data retention memory.



PFA9401-H6  YOCTO I-O D4 8÷32V 2AI 4DI 2RO INPUT-OUTPUT DEVICE

YOCTO I-O D4 8÷32V 2AI 4DI 2RO INPUT-OUTPUT DEVICE

Cod. PFA9401-H6

Multifunctional I/O device for RS485 networks. Built-in calendar/clock and data retention memory.



PFA9401-M6  YOCTO I-O D4 8÷32V 2AI 6DI INPUT-OUTPUT DEVICE

YOCTO I-O D4 8÷32V 2AI 6DI INPUT-OUTPUT DEVICE

Cod. PFA9401-M6

Multifunctional I/O device for RS485 networks. Built-in calendar/clock and data retention memory.



PFAT0IS-03 LED PULSE COUNTER

LED PULSE COUNTER

Cod. PFAT0IS-03

Optional probe for the multifunction device Yocto I-O. Pulse counter from the LEDs of electrical energy meters.


CONTACTS

export.electrex.akse

Tel: +39 0522 924244

Fax: +39 0522 924245

export@electrex.it

 
Banner

Newsletter

Enter your email address to have Electrex news, special offers and product announcements delivered directly to your inbox.

Name & Surname *
Country *
Email *


Companies using our solutions:

Electrex is a brand of Akse s.r.l. - Via Aldo Moro, 39 - Reggio Emilia - Italy - Tel: +39 0522 924244 Fax: +39 0522 924245 - VAT IT01544980350 - info@electrex.it
Joomla! is Free Software released under the GNU/GPL License.