|
|
ATTO D4 RS485 230-240V TRANSDUCER / ENERGY ANALYZER RS485 port (Modbus protocol), DIN rail mount 4 modules. 230-240V Power Supply. |
||
|
|
ATTO D4 RS485 230-240V 1DI 2DO TRANSDUCER / ENERGY ANALYZER RS485 port (Modbus protocol), DIN rail mount 4 modules.1 digital Input, 2 isolated digital outputs. 230-240V Power Supply. |
||
|
|
|
ATTO D4 RS485 230-240V 2AO4-20mA TRANSDUCER / ENERGY ANALYZER RS485 port (Modbus protocol), DIN rail mount 4 modules. 2 passive 4-20 mA analogue outputs. 230-240V Power Supply. |
|
|
|
ATTO D4 70A RS485 230-240V TRANSDUCER / ENERGY ANALYZER Transducer / Analyser DIN rail mount 4 modules. RS485 port. 70 A direct input via external CTs (1 included). 230-240V Power supply. |
||
![]() |
ATTO D4 70A RS485 230-240V 1DI 2DO TRANSDUCER / ENERGY ANALYZER Transducer / Analyser DIN rail mount 4 modules. RS485 port, 1 Digital Input, 2 Digital Outputs. 70 A direct input via external CTs (1 included). 230-240V Power supply. |
||
![]() |
ATTO D4 70A RS485 230-240V 1DI 2DO SELF POWERED TRANSDUCER / ENERGY ANALYZER Transducer / Analyser DIN rail mount 4 modules. RS485 port, 1 Digital Input, 2 Digital Outputs. 70 A direct input via external CTs (1 included). 230-240V Power supply. |
||
![]() |
Encapsulated 70A CT for FEMTO D4 and ATTO D4 70A meters. 9mm hole diameter. |
||
![]() |
ATTO D4 DC RS485 230-240V TRANSDUCER / ENERGY ANALYZER DC energy transducer / analyzer suitable for photovoltaic or battery systems. 60mV or 100mV current input for the shunts (not included - see Shunt section). Built in RS485 port. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply. |
||
![]() |
ATTO D4 DC RS485 230-240V 1DI 2DO TRANSDUCER / ENERGY ANALYZER DC energy transducer / analyzer suitable for photovoltaic or battery systems. 60mV or 100mV current input for the shunts (not included - see Shunt section). Built in RS485 port, 1 digital input and 2 digital outputs. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply. |
||
![]() |
ATTO D4 DC RS485 18÷60VDC 1DI 2DO TRANSDUCER / ENERGY ANALYZER DC energy transducer / analyzer suitable for photovoltaic or battery systems. 60mV or 100mV current input for the shunts (not included - see Shunt section). Built in RS485 port, 1 digital input and 2 digital outputs. DIN rail mount type, 4 DIN modules size. 18÷60Vdc power supply. |
||
![]() |
ATTO D4 DC 3I RS485 230-240V TRANSDUCER / ENERGY ANALYZER DC energy transducer / analyzer suitable for measuring simultaneously 3 strings in the Photovoltaic systems. 3 x 60mV or 100mV current inputs for the shunts (not included - see Shunt section). Built in RS485 port. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply. |
||
![]() |
ATTO D4 DC 3I RS485 230-240V 1DI 2DO TRANSDUCER / ENERGY ANALYZER DC energy transducer / analyzer suitable for measuring simultaneously 3 strings in the Photovoltaic systems. 3 x 60mV or 100mV current inputs for the shunts (not included - see Shunt section). Built in RS485 port, 1 digital input and 2 digital outputs. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply. |
||
![]() |
ATTO D4 DC 3I RS485 230-240V 1DI 2DO SELF POWERED ENERGY TRANSDUCER / ENERGY ANALYZER DC energy transducer / analyzer suitable for measuring simultaneously 3 strings in the Photovoltaic systems. 3 x 60mV or 100mV current inputs for the shunts (not included - see Shunt section). Built in RS485 port,1 active digital input self powered and 2 digital outputs. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply. |
||
![]() |
ATTO D4 DC 3I RS485 230-240V 2DI 1RO TRANSDUCER / ENERGY ANALYZER DC energy transducer / analyzer suitable for measuring simultaneously 3 strings in the Photovoltaic systems. 3 x 60mV or 100mV current inputs for the shunts (not included - see Shunt section). Built in RS485 port, 2 active digital input self powered and 1 relay output. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply. |
||
![]() |
ATTO D4 DC ECOALARM RS485 900V/300V Anti-theft system with verification of the presence of photovoltaic panels and a voltage divider up to 900Vdc to be used together with the Atto DC 3I. Generates an e-mail alarm if connected to an Yocto net with the Mail Alarm option. 3/1 ratio (e.g. 900Vdc in input >> 300Vdc in output). Built in RS485 port. DIN rail mount type, 4 DIN modules size. |
||
![]() |
ATTO D4 DC ECOALARM 6I RS485 900V/300V Anti-theft system with verification of the presence of photovoltaic panels and a voltage divider up to 900Vdc to be used together with 2 x Atto DC 3I. Generates an e-mail alarm if connected to an Yocto net with the Mail Alarm option. 3/1 ratio (e.g. 900Vdc in input >> 300Vdc in output). Built in RS485 port. DIN rail mount type, 4 DIN modules size. |
||
![]() |
VOLTAGE DIVIDER D2 DC 900V/300V Voltage divider for FEMTO DC and ATTO DC up to 900 V. 3:1 ratio. 2 DIN modules size. |
||
![]() |
ATTO D4 E-WI HI 230-240V TRANSDUCER / ENERGY ANALYZER Single - three phase transducer/analyzer. Built-in RS485 serial port (Modbus protocol). Transceives the data via radio waves (wireless) using the E-Wi protocol. DIN rail mount type, size 4 DIN modules D4). Power supply 230-240Vac. |
||
![]() |
ATTO D4 70A E-WI HI 230-240V TRANSDUCER / ENERGY ANALYZER Single - three phase transducer/analyzer. Suitable with external CT 70A cod. PFAE000-00 (1 already supplied and included in the packaging). Built-in RS485 serial port (Modbus protocol). Transceives the data via radio waves wireless) using the E-Wi protocol. DIN rail mount type, size 4 DIN modules (D4). Power supply 230-240Vac. |
||
![]() |
ATTO D4 DC E-WI HI 230-240V TRANSDUCER / ENERGY ANALYZER DC energy transfucer / analyzer suitable for photovoltaic or battery systems. 60mV or 100mV current input for the shunts (not included - see Shunt section). Built in RS485 port. Transceives the data via radio waves (wireless) using the E-Wi protocol. DIN rail mount type, 4 DIN modules size. 230-240 Vac power supply. |
||
![]() |
FAST D6 H 85÷265V TRANSDUCER / ENERGY ANALYZER DIN rail mount 6 modules. 85-265Vac/100-374Vdc power supply. Including FFT harmonics readings per phase of U, I & P up to 31st order + direction of flow.
|
||
![]() |
RS 485 output module for Fast, Flash and X3M DIN rail mount instruments type.
|
||
![]() |
RS 232 output module for Fast, Flash and X3M DIN rail mount instruments type. |
||
![]() |
2 x 4-20 mA programmable analogue output module for Fast, Flash and X3M DIN rail mount instruments type. |
||
![]() |
2 digital Inputs + 2 relay Outputs 30V 2A for Fast, Flash and X3M instrument type.
|
||
![]() |
ADAPTER CABLE INTERFACE 96 / DIN Cable for use of 96 options into DIN meters. |
| X3M D6 85÷265V ENERGY DATA MANAGER Cod. PFE840-00 |
|
LCD display. DIN rail mount 6 modules. 85-265Vac/100-374Vdc power supply |
CONTACTS
Newsletter
Intelligent Transducers
OVER 60 READINGS, MIN-MAX U, MAX., THERMAL & NEUTRAL CURRENT, PHASE THD-I, THD-U, PEAK POWER, MD, ROLLING DEMAND, IMPORT/EXPORT DEMAND, PHASE, PARTIAL AND TOTAL ACTIVE ENERGY, 2-4 QUADRANT ENERGIES (EA, ER) RMS MEASUREMENT TO 31ST HARMONIC.
0,5 % ACCURACY ON V AND I. CLASS 1 ACCURACY ON ACTIVE ENERGY AND CL. 2 ON REACTIVE ENERGY (EN62053-21).
SINGLE-PH, 2-PH, BAL. / UNBAL. 3-PH (MAX. 500V PH-PH), 2, 3 & 4 WIRE, LT AND HT SYSTEMS, ../1-5A CT INPUT. TEMP. RANGE -10+50°C. 230-240VAC.
2 YEARS WARRANTY.




























